Robot Pi Shop

MQ137 Ammonia Gas Detection Sensor Module

$22.99

Shipping calculated at checkout.

Quantity

The MQ137 Ammonia (NH₃) Gas Sensor Module is a semiconductor gas sensor designed to detect ammonia concentrations in the surrounding air. It uses a metal oxide sensing element whose electrical resistance changes when exposed to ammonia gas.

The MQ137 provides sensitivity to ammonia and is suitable for environmental monitoring experiments, agricultural sensing projects, laboratory research, and educational electronics applications.

The module features analog and digital outputs, an adjustable detection threshold, onboard indicator LEDs, and a compact PCB design. It can be interfaced with Arduino, ESP32, Raspberry Pi, and other microcontroller-based monitoring systems using appropriate circuitry.

Key Features

  • Ammonia Gas Detection: Designed primarily for detecting ammonia (NH₃).
  • Semiconductor Technology: Uses a metal oxide gas-sensitive sensing element.
  • Analog Output (AO): Provides a variable voltage related to sensor resistance and gas concentration.
  • Digital Output (DO): Provides a HIGH/LOW signal based on an adjustable detection threshold.
  • Adjustable Threshold: Onboard potentiometer allows adjustment of the digital switching point.
  • 5V DC Operation: Suitable for common microcontroller development systems.
  • Onboard LED Indicators: Power and digital output status indication.
  • Fast Sensor Response: Responds to changes in ammonia concentration.
  • Compact PCB Design: Suitable for embedded electronics and sensing prototypes.
  • Mounting Holes: Allows installation in project enclosures.
  • Microcontroller Compatibility: Can interface with Arduino, ESP32, and Raspberry Pi using appropriate circuitry.

Technical Specifications

Specification Details
Model MQ137
Sensor Type Ammonia Gas Sensor
Target Gas Ammonia (NH₃)
Sensor Technology Metal Oxide Semiconductor (MOS)
Typical Detection Range 5–500 ppm NH₃
Module Operating Voltage 5V DC
Reported Module Current Approximately 150 mA
Analog Output Variable Voltage
Digital Output HIGH/LOW Logic
Digital Output Levels Approximately 0V or 5V
Detection Threshold Adjustable Potentiometer
Sensor Heating Internal Heating Element
Preheating Required Before Stable Measurements
Interface Analog and Digital
Connection 4-Pin Interface
PCB Mounting Mounting Holes Provided

Pin Configuration

Pin Description
VCC 5V DC Power Supply
GND Ground
AO Analog Sensor Output
DO Digital Threshold Output

Arduino UNO Connection Example

MQ137 Pin Arduino UNO
VCC 5V
GND GND
AO A0
DO D2 (Optional)

Arduino can read the analog output to monitor relative changes in ammonia concentration or use the digital output to detect when the adjustable threshold is reached.

Note: Accurate ammonia concentration measurements require calibration and appropriate signal processing.

ESP32 Connection Example

MQ137 Pin ESP32
VCC 5V
GND GND
AO GPIO34 Through Voltage Divider
DO Digital GPIO Through Level Shifter

Important: ESP32 GPIO pins operate at 3.3V. The MQ137 module may produce output signals up to 5V, so appropriate voltage-level protection is required.

Raspberry Pi Compatibility

The MQ137 can be connected to Raspberry Pi boards using additional interface components.

  • Analog Reading: Requires an external ADC such as ADS1115 or MCP3008.
  • Digital Reading: Requires suitable voltage-level shifting if the digital output exceeds 3.3V.
  • Power Supply: Requires a suitable 5V DC supply.

Applications

  • Ammonia gas sensing experiments
  • Agricultural environmental monitoring prototypes
  • Livestock facility air monitoring research
  • Poultry farm environmental sensing projects
  • Wastewater treatment research
  • Laboratory ammonia sensing experiments
  • Arduino gas detection systems
  • ESP32 IoT monitoring applications
  • Raspberry Pi sensor projects
  • Educational electronics experiments
  • Industrial gas monitoring research
  • Embedded gas sensing systems
  • Air quality monitoring prototypes

Important Notes

  • The MQ137 is designed primarily for ammonia (NH₃) detection.
  • The sensor may respond to other gases and cannot reliably identify individual gases in a mixed environment.
  • The analog output does not directly represent ammonia concentration in ppm. Calibration is required.
  • The onboard potentiometer adjusts the digital switching threshold, not the sensor's underlying sensitivity.
  • Initial preheating and sensor conditioning are necessary before stable measurements can be obtained.
  • The approximately 20-second warm-up sometimes listed for breakout modules does not replace full sensor conditioning.
  • Temperature, humidity, and other environmental conditions may affect sensor readings.
  • The internal heating element becomes warm during operation.
  • Do not connect 5V output signals directly to 3.3V-only microcontroller GPIO pins.
  • Ammonia is a hazardous gas at elevated concentrations. Exposure must not be assessed using an uncalibrated hobby sensor.
  • This module is not a certified ammonia safety detector and must not replace approved industrial gas monitoring equipment.
  • Package Includes
  • 1 × MQ137 Ammonia Gas Sensor Module