ZM194-D9Y 3-Phase Multifunction Digital Power Meter with 3 × 300A/5A Split-Core CTs
The ZM194-D9Y Multifunction Digital Power Meter is designed for comprehensive monitoring of three-phase electrical systems. It can measure and display key electrical parameters including voltage, current, active power, reactive power, power factor, frequency, and electrical energy.
This kit includes three ZDKCT38M 300A/5A split-core current transformers, allowing current measurement up to 300A without requiring the primary power cable to be disconnected during CT installation.
The meter also supports RS485 Modbus-RTU communication, making it suitable for integration with industrial monitoring, automation, energy-management, and data-acquisition systems.
Technical Specifications
-
Meter Model: ZM194-D9Y
-
Meter Type: Multifunction Digital Power Meter
-
System: Three-Phase
-
Wiring: Three-Phase 3-Wire or Three-Phase 4-Wire
-
Rated Voltage Input: AC 380V
-
Rated Current Input: AC 5A
-
CT Ratio Supplied: 300A/5A
-
Auxiliary Power Supply: AC/DC 85-265V
-
Input Frequency: 45-65Hz
-
Display: LCD Digital Display
-
Current Accuracy: Class 0.5
-
Voltage Accuracy: Class 0.5
-
Active Power Accuracy: Class 0.5
-
Reactive Power Accuracy: Class 0.5
-
Power Factor Accuracy: Class 0.5
-
Frequency Accuracy: ±0.02Hz
-
Active Energy Accuracy: Class 0.5S / 0.2S as specified
-
Reactive Energy Accuracy: Class 1.0 / 2.0 as specified
-
Auxiliary Power Consumption: <4VA
Input Characteristics
-
Voltage Overload – Continuous: 1.2 × Rated Voltage
-
Voltage Overload – Instantaneous: 2 × Rated Voltage for 1 second
-
Current Overload – Continuous: 1.2 × Rated Current
-
Current Overload – Instantaneous: 10 × Rated Current for 5 seconds
-
Voltage Input Consumption: <1VA per phase
-
Current Input Consumption: <0.4VA per phase
-
Voltage Input Impedance: >300kΩ
-
Current Input Impedance: <20mΩ
RS485 Modbus Communication
-
Interface: RS485
-
Protocol: Modbus RTU
-
Communication Channels: 1
-
Baud Rate: 1200-9600bps
-
Default Baud Rate: 2400bps
The RS485 interface allows the meter to communicate with compatible PLCs, industrial computers, monitoring systems, gateways, data loggers, and building or energy-management systems using Modbus RTU.
Outputs
-
Relay Outputs: Up to 3 channels as specified
-
Relay Contact Rating: AC 250V / 5A or DC 30V / 5A
-
Analog Output: 1 channel
-
Analog Current Output: 0-20mA or 4-20mA
-
Analog Voltage Output: 0-5V or 0-10V
-
Energy Pulse Outputs: 2 channels
-
Pulse Constant: 8000 imp/kWh or kvarh as specified
Output functions and installed options may depend on the exact meter configuration supplied.
Environmental Specifications
-
Operating Temperature: -10°C to +55°C
-
Storage Temperature: -25°C to +70°C
-
Relative Humidity: <93% RH
-
Maximum Installation Altitude: <2500m
-
Environment: Non-corrosive atmosphere
Electrical Safety
-
Insulation Resistance: >100MΩ
-
AC Withstand Voltage: 2kV
-
Electrostatic Discharge Immunity: Class 4 as specified
-
Electrical Fast Transient Immunity: Class 4 as specified
-
Surge Immunity: Class 4 as specified
Meter Dimensions
The ZM194-D9Y series may be available in several panel sizes depending on the selected version:
-
120 × 120mm Panel: Approx. 111 × 111mm cutout
-
96 × 96mm Panel: Approx. 92 × 92mm cutout
-
80 × 80mm Panel: Approx. 76 × 76mm cutout
-
72 × 72mm Panel: Approx. 68 × 68mm cutout
The provided dimensional data specifically identifies an 80 × 80mm version with approximately 76 × 76mm panel cutout. Confirm the selected meter size before preparing the panel opening.
ZDKCT38M 300A/5A Split-Core Current Transformers
The included ZDKCT38M split-core current transformers allow current measurement without disconnecting the primary conductor. The hinged/open-core design can be installed around an existing cable, simplifying installation and maintenance.
Each CT converts primary current up to 300A into a standard 5A secondary signal for the multifunction meter.
Current Transformer Specifications
-
Model: ZDKCT38M
-
Type: Split-Core / Open-Type Current Transformer
-
Primary Current Range: 0-300A
-
Secondary Rated Current: 5A
-
CT Ratio: 300A/5A
-
Accuracy: Class 0.5 as specified
-
Inner Opening Diameter: Approx. 38mm
-
Operating Frequency: 20-400Hz
-
Ambient Temperature: -40°C to +85°C
-
Relative Humidity: ≤80% at 40°C
-
Insulation Class: Class B (130°C)
-
Insulation Resistance: >1000MΩ under specified conditions
-
Dielectric Withstand: 6000V AC / 50Hz for 1 minute as specified
-
Flame-Retardant Rating: UL 94 V-0 as specified
-
Internal Resistance: Approx. 10Ω as specified
-
Installation: Split-core clamp around primary conductor
Applications
Suitable for three-phase distribution panels, industrial machinery, factories, building energy monitoring, electrical cabinets, power-management systems, automation systems, solar installations, generators, motor control panels, energy-consumption monitoring, and Modbus-based data acquisition.
The combination of multifunction measurement, RS485 communication, relay outputs, analog output, and energy pulse outputs makes the meter suitable for both local electrical monitoring and integration into larger automation systems.
Important CT Installation & Safety Notes
The primary power conductor passes through the opening of the current transformer. The primary conductor itself is not electrically connected to the CT secondary terminals.
The 5A secondary of a current transformer must never be left open-circuit while significant primary current is flowing, as potentially dangerous voltages can develop across the CT secondary.
When installing or servicing the CT secondary wiring, follow proper CT shorting and isolation procedures.
This equipment is intended for use with potentially hazardous mains and three-phase voltages. Installation and commissioning should be performed by a qualified electrician or electrical technician using appropriate protection and isolation procedures.
Package Includes
1 × ZM194-D9Y Multifunction Digital Power Meter
3 × ZDKCT38M 300A/5A Split-Core Current Transformers
1 × English User Manual