LSYZ-1 Side-Mount Float Level Switch – Liquid Level Sensor
The LSYZ-1 Float Level Switch is a compact mechanical liquid level sensor designed to detect changes in liquid levels inside tanks, reservoirs, and containers.
Featuring a side-mount design, a polypropylene (PP) housing, and a magnetic reed-switch mechanism, the LSYZ-1 provides a simple ON/OFF switching signal as the liquid level rises or falls.
It is suitable for water level monitoring, tank automation, liquid level alarms, and pump control circuits using an appropriate relay or controller.
Key Features
-
Model: LSYZ-1
- Side-mounted float level switch
- Mechanical magnetic float operation
- Normally Open (NO) or Normally Closed (NC) operation, depending on float orientation
- Polypropylene (PP) housing
- Maximum listed switching voltage: 110V DC
- Maximum listed switching current: 0.5A
- Maximum listed contact rating: 10W
- Operating temperature: -10°C to +80°C
- Two-wire switching connection
- Compact design for tank installation
- No external power required for the switch mechanism
- Suitable for Arduino, ESP32, PLC, and relay-based monitoring circuits
Technical Specifications
| Parameter |
Specification |
| Model |
LSYZ-1 |
| Product Type |
Float Level Switch |
| Detection Method |
Magnetic Float / Reed Switch |
| Installation Type |
Side Mount |
| Housing Material |
Polypropylene (PP) |
| Switching Function |
NO or NC, Depending on Installation and Float Orientation |
| Maximum Switching Voltage |
110V DC, as Listed |
| Maximum Switching Current |
0.5A, as Listed |
| Maximum Contact Power |
10W |
| Operating Temperature |
-10°C to +80°C |
| Wire Type |
UL3266, 22AWG, as Listed |
| Cable Length |
Approximately 300mm |
| Electrical Connection |
2-Wire |
| Output Type |
Dry Contact |
| Power Supply |
Not Required for Switch Operation |
| Suitable Liquid |
Compatible Non-Corrosive Liquids, Subject to Material Compatibility |
| Mounting Position |
Side of Tank |
Important: The voltage, current, and power ratings must all be respected simultaneously. A 10W contact rating does not permit switching 0.5A at 110V DC.
How It Works
The LSYZ-1 uses a buoyant float containing a magnet and an internal reed switch.
As the liquid level changes, the float moves and activates or deactivates the reed switch.
The switch provides a simple electrical contact signal that can be monitored by a microcontroller, PLC, or alarm circuit.
Switching Operation
-
Normally Open (NO): The electrical contact closes when the float reaches the activation position.
-
Normally Closed (NC): The electrical contact opens when the float reaches the activation position.
On compatible models, the switching logic can be changed by reversing the float orientation.
Verify the actual switching behavior with a multimeter before installation.
Wiring Configuration
The LSYZ-1 typically has two wires connected to an internal reed switch.
| Wire |
Function |
| Wire 1 |
Switch Contact |
| Wire 2 |
Switch Contact |
The contacts are generally non-polarized.
The switch does not generate an analog voltage or directly measure the liquid level in centimeters.
Arduino Connection Example
The float switch can be used with an Arduino Uno to detect whether liquid has reached a specific level.
| Float Switch |
Arduino Uno |
| Wire 1 |
GND |
| Wire 2 |
D2 |
Configure the input with the internal pull-up resistor.
Arduino Example Code
const int floatSwitchPin = 2;
void setup() {
pinMode(floatSwitchPin, INPUT_PULLUP);
Serial.begin(9600);
}
void loop() {
if (digitalRead(floatSwitchPin) == LOW) {
Serial.println("Float switch contact CLOSED");
} else {
Serial.println("Float switch contact OPEN");
}
delay(200);
}
The relationship between contact state and liquid level depends on the float orientation and installation.
ESP32 Compatibility
The LSYZ-1 can also be connected to an ESP32 digital input.
For a simple low-voltage connection:
- Connect one switch wire to GND.
- Connect the other wire to an appropriate GPIO.
- Configure a suitable pull-up resistor to 3.3V.
- Read the contact state using the ESP32 firmware.
Use software debouncing if needed to prevent false transitions.
Applications
- Water Tank Level Monitoring
- Liquid Level Alarms
- Reservoir Monitoring
- Water Pump Control Systems
- Automatic Filling Systems
- Aquarium Monitoring
- Industrial Liquid Level Detection
- Arduino and ESP32 Projects
- PLC Automation
- DIY Water Level Indicators
- Educational Electronics
Important Notes
-
This sensor provides single-point liquid level detection, not continuous level measurement.
- It does not require a power supply when used as a dry-contact switch.
- The maximum contact rating is 10W, as listed.
- Do not connect a water pump or other high-power load directly to the float switch.
- Use an appropriately rated relay, contactor, or motor-control circuit for pump applications.
- Confirm the NO/NC behavior before installation.
- Verify that the liquid is chemically compatible with the PP housing and other wetted components.
- Do not assume compatibility with fuels, solvents, drinking water, or corrosive liquids without manufacturer confirmation.
- Avoid exceeding the rated operating temperature.
- Ensure the mounting seal is properly installed to prevent leakage.
- Confirm the mounting-hole dimensions before drilling the tank.
- Do not use the switch as the sole protection device in safety-critical systems.
Package Includes
1 × LSYZ-1 Side-Mount Float Level Switch