MH1210W Digital Temperature Controller – Heating & Cooling Thermostat with NTC Sensor
The MH1210W Digital Temperature Controller is a compact electronic thermostat designed for automatic heating and cooling control in refrigeration, industrial equipment, water tanks, incubators, and temperature-regulated systems.
Featuring a digital LED display, an external NTC temperature sensor, and a built-in relay output, the MH1210W continuously monitors temperature and switches connected heating or cooling equipment according to user-defined settings.
The controller operates from a 90–250V AC power supply and supports temperature measurement from -50°C to +110°C. It includes adjustable temperature settings, calibration, delay protection, and heating/cooling operating modes.
Its panel-mount design makes it suitable for control cabinets, refrigeration equipment, and DIY temperature control applications.
Key Features
-
Digital Temperature Control: Automatically controls heating or cooling equipment according to the configured temperature.
-
Heating and Cooling Modes: Supports both heating and refrigeration applications.
-
Wide Measurement Range: Measures temperatures from -50°C to +110°C.
-
LED Digital Display: Provides clear temperature readings and parameter settings.
-
External NTC Sensor: Uses a 10kΩ NTC temperature probe for temperature monitoring.
-
Relay Output: Switches connected electrical loads according to temperature settings.
-
Adjustable Temperature Settings: Allows users to configure the target temperature and switching differential.
-
Temperature Calibration: Supports adjustment of the displayed temperature reading.
-
Delay Protection: Helps prevent excessive switching in refrigeration applications.
-
Compact Panel-Mount Design: Suitable for equipment panels and control enclosures.
-
AC Power Supply: Operates from 90–250V AC, 50/60Hz.
-
Low Power Consumption: Rated below 3W.
Technical Specifications
| Parameter |
Specification |
| Model |
MH1210W |
| Product Type |
Digital Temperature Controller |
| Control Function |
Heating / Cooling |
| Supply Voltage |
90–250V AC ±10% (listed) |
| Supply Frequency |
50/60Hz |
| Rated Output Current |
10A |
| Power Consumption |
Less than 3W |
| Temperature Measurement Range |
-50°C to +110°C |
| Display Resolution |
0.1°C |
| Listed Measurement Accuracy |
±0.3°C |
| Control Precision |
1°C (listed) |
| Temperature Sensor |
NTC 10kΩ, B3435 |
| Sensor Cable Length |
1m |
| Output Type |
Relay |
| Listed Relay Load |
10A at 220V AC, Normally Open |
| Operating Ambient Temperature |
-20°C to +70°C |
| Maximum Operating Humidity |
90% RH, Non-Condensing |
| Temperature Calibration |
Supported |
| Delay Protection |
Supported |
| Factory Reset |
Supported |
| Display Type |
Digital LED |
| Dimensions |
85 × 75 × 35mm |
| Mounting Type |
Panel / Equipment Installation |
Note: The electrical and temperature specifications are based on the supplied product information. Actual relay capacity for inductive loads such as compressors and motors may be lower than the listed resistive-load rating.
Operating Functions
1. Heating Mode
In heating mode, the controller activates the connected heating equipment when the measured temperature falls below the configured switching threshold.
The heater switches off when the target temperature is reached, according to the controller's configured differential.
2. Cooling Mode
In cooling mode, the controller activates the connected cooling equipment when the measured temperature rises above the configured switching threshold.
The cooling equipment switches off when the temperature returns to the configured target level.
3. Temperature Calibration
The controller supports temperature calibration to compensate for small differences between the displayed temperature and a reference thermometer.
4. Delay Protection
The delay function helps reduce rapid relay switching and can be useful for refrigeration systems.
5. Factory Reset
The controller supports restoring configuration parameters to their default settings.
Connection and Wiring
The MH1210W uses separate connections for the AC power supply, temperature sensor, and relay-controlled load.
| Connection |
Function |
| AC Power Input |
Supplies power to the controller |
| NTC Sensor Input |
Connects the external temperature probe |
| Relay Output |
Switches the connected heating or cooling equipment |
| Relay Common |
Common connection for the relay switching circuit |
| Relay Normally Open |
Closes when the relay is activated |
Important: Terminal numbering and the exact wiring arrangement must be verified using the diagram printed on the supplied controller.
The relay is a switching contact and should not be assumed to provide a separate powered output.
Basic Operating Instructions
- Install the controller in a suitable equipment panel or enclosure.
- Connect the NTC temperature sensor to the designated sensor terminals.
- Connect the controller to the specified AC power supply.
- Connect the heating or cooling load through the relay circuit according to the manufacturer's wiring diagram.
- Select the required heating or cooling operating mode.
- Set the desired target temperature.
- Configure the switching differential and delay settings as required.
- Allow the controller to monitor the temperature and automatically operate the connected equipment.
Applications
- Refrigerators and freezers
- Industrial chillers
- Water tank temperature control
- Heating equipment
- Cooling and ventilation systems
- Incubators
- Greenhouse temperature regulation
- Temperature-controlled cabinets
- Laboratory equipment
- Industrial process temperature monitoring
- DIY heating and cooling projects
- Electronic temperature regulation systems
- Small refrigeration equipment
- Environmental control applications
Important Notes
-
High Voltage Warning: The controller operates from AC mains voltage. Installation and wiring should be performed by a qualified person.
- Disconnect the power supply before installing or modifying connections.
- Verify the controller's terminal diagram before connecting AC power or external equipment.
- The listed 10A relay rating should not automatically be applied to inductive loads such as compressors, pumps, and motors.
- Use a suitable external contactor or relay for loads exceeding the controller's switching capability.
- Install appropriate circuit protection, including a fuse or circuit breaker.
- The NTC sensor should be positioned where it accurately represents the temperature being controlled.
- Avoid placing the sensor directly beside heating elements unless required by the application.
- The controller should be installed in a suitable enclosure to prevent accidental contact with live electrical terminals.
- The controller itself is not specified as waterproof.
- Do not expose the controller to condensation, excessive humidity, or temperatures outside its operating range.
- Delay protection should be configured appropriately when controlling refrigeration compressors.
- The temperature sensor and controller are not intended for certified medical or life-safety applications.
- The device is a standalone temperature controller and does not require Arduino or another microcontroller for normal operation.
- The controller does not provide a documented USB, Wi-Fi, or serial communication interface.
Package Includes
- 1 × MH1210W Digital Temperature Controller
- 1 × External NTC Temperature Sensor Probe with Cable
Note: External contactors, power cables, circuit protection devices, and heating or cooling equipment are not included.