14FC-2C-AC220V Mini Electromagnetic Relay – DPDT 5A
The 14FC-2C-AC220V Mini Electromagnetic Relay is a compact electromechanical switching component designed for electrical control, industrial automation, and electronic equipment.
Featuring a 220V AC operating coil and a double-pole double-throw (DPDT) contact configuration, this relay allows two independent circuits to be switched simultaneously using a single control signal.
The relay features a transparent protective housing, making the internal coil and mechanical switching contacts visible. Its compact PCB-mount design makes it suitable for control boards, switching circuits, and electrical automation applications.
With contact ratings of 5A at 250V AC and 5A at 30V DC, the relay can be used for switching compatible electrical loads within its specified ratings.
Key Features
-
220V AC Coil: Designed for operation with a nominal 220V AC control supply.
-
DPDT Contact Configuration: Two independent changeover contact sets.
-
5A Switching Capacity: Rated for 5A at 250V AC or 30V DC.
-
Electromagnetic Operation: Uses an energized coil to mechanically switch electrical contacts.
-
Transparent Housing: Allows visual inspection of the internal relay mechanism.
-
Electrical Isolation: Provides galvanic separation between the coil and switching contacts.
-
PCB-Mount Design: Suitable for integration into compatible printed circuit boards.
-
Compact Construction: Designed for space-conscious electrical control applications.
-
Multiple Switching Functions: Supports normally open and normally closed circuit operation.
Technical Specifications
| Parameter |
Specification |
| Product Type |
Electromagnetic Relay |
| Model |
14FC-2C-AC220V |
| Relay Series |
14FC |
| Coil Voltage |
220V AC |
| Coil Type |
AC Electromagnetic |
| Contact Configuration |
DPDT (2 Form C) |
| Number of Poles |
2 |
| Contact Sets |
2 Changeover Contacts |
| Rated Contact Current |
5A |
| AC Contact Rating |
5A at 250V AC |
| DC Contact Rating |
5A at 30V DC |
| Switching Operation |
Electromechanical |
| Mounting Type |
PCB Through-Hole |
| Housing |
Transparent Protective Case |
| Connection Type |
Solder Pins |
| Coil Power Consumption |
Not Confirmed |
| Operating Temperature |
Not Confirmed |
| Dimensions |
Not Confirmed |
Note: Contact ratings apply under the manufacturer's specified test conditions. Actual switching capability depends on the type of load, operating conditions, and electrical characteristics.
Contact Configuration
The relay uses a DPDT (Double-Pole Double-Throw) configuration consisting of two independent changeover contact sets.
| Terminal |
Function |
| Coil A1 |
Coil Supply Connection |
| Coil A2 |
Coil Supply Connection |
| COM1 |
Common Contact – Pole 1 |
| NC1 |
Normally Closed Contact – Pole 1 |
| NO1 |
Normally Open Contact – Pole 1 |
| COM2 |
Common Contact – Pole 2 |
| NC2 |
Normally Closed Contact – Pole 2 |
| NO2 |
Normally Open Contact – Pole 2 |
Note: These are functional terminal designations, not a confirmed physical pin layout. Refer to the markings or datasheet for the exact pin positions.
Operating Principle
When the relay coil is not energized:
- COM1 is connected to NC1.
- COM2 is connected to NC2.
- Normally open contacts remain disconnected.
When 220V AC is applied to the relay coil:
- The electromagnetic mechanism activates.
- COM1 switches from NC1 to NO1.
- COM2 switches from NC2 to NO2.
- The relay remains activated while the coil is energized.
When coil power is removed, the relay returns to its normal position.
Applications
- Industrial automation
- Electrical control panels
- Relay switching circuits
- Equipment control systems
- Electrical machinery
- HVAC control circuits
- Lighting control systems
- Power switching applications
- Electronic control boards
- Electrical maintenance and repair
- Automated switching equipment
- DIY electrical control projects
Important Notes
-
High Voltage Warning: The relay coil operates at 220V AC and must only be connected by qualified personnel using appropriate electrical safety precautions.
- Do not connect the 220V AC coil directly to Arduino, ESP32, Raspberry Pi, or other microcontroller GPIO pins.
- A suitable isolated interface or control circuit is required for microcontroller-based operation.
- The relay contact rating must not be exceeded.
- Inductive loads such as motors, transformers, and solenoids may require additional contact protection or derating.
- The 250V AC and 30V DC ratings refer to the switching contacts, not the coil supply.
- Ensure proper electrical insulation and safe PCB clearances when working with mains voltage.
- The exact physical pinout must be verified before PCB installation.
- Disconnect the electrical supply before wiring, testing, or servicing.
- The transparent housing does not make exposed terminals safe to touch.
- Use suitable circuit protection, including fuses or circuit breakers where required.
- Do not use the relay in safety-critical applications without verifying the manufacturer's specifications and relevant certifications.
Package Includes