Robot Pi Shop

MQ-6 - LPG, Butane Gas

$1.99

Shipping calculated at checkout.

Quantity

The MQ-6 LPG Gas Sensor Module is a semiconductor gas detection module designed primarily for detecting liquefied petroleum gas (LPG), propane, butane, and isobutane in the surrounding environment.

The sensor uses a Metal Oxide Semiconductor (MOS) sensing element made from tin dioxide (SnO2). Its electrical resistance changes when exposed to combustible gases, allowing the module to monitor relative changes in gas concentration.

The MQ-6 offers high sensitivity to LPG-related gases and comparatively lower sensitivity to alcohol vapors and smoke under specified conditions.

Featuring analog and digital outputs, an adjustable digital detection threshold, and 5V operation, the module can be integrated with Arduino, ESP32, Raspberry Pi (with additional interfacing), and other compatible microcontrollers.

It is suitable for educational gas detection projects, IoT monitoring prototypes, and embedded sensing applications.

Key Features

  • LPG Detection: Designed for detecting liquefied petroleum gas.
  • Propane and Butane Sensitivity: Suitable for monitoring propane, butane, and isobutane.
  • High Gas Sensitivity: Responds to changes in combustible gas concentrations.
  • Analog Output (AO): Provides a variable voltage related to gas concentration.
  • Digital Output (DO): Provides a HIGH/LOW signal based on an adjustable detection threshold.
  • Adjustable Detection Threshold: Onboard potentiometer allows digital trigger adjustment.
  • 5V Operating Voltage: Compatible with common microcontroller projects using appropriate interfacing.
  • Reduced Cross-Sensitivity: Generally less sensitive to alcohol vapors and smoke than to its primary target gases.
  • Onboard Indicator LEDs: Power and digital detection status indication.
  • Compact PCB Design: Suitable for embedded electronics and sensor projects.
  • Reusable Sensor: Designed for repeated gas detection measurements.

Technical Specifications

Specification Details
Product Model MQ-6
Sensor Type Combustible Gas Sensor
Sensor Technology Metal Oxide Semiconductor (MOS)
Sensing Material Tin Dioxide (SnO2)
Operating Voltage 5V DC
Primary Target Gas LPG
Detectable Gases Propane, Butane, Isobutane
Typical Detection Range 200–10,000 ppm LPG
Analog Output Variable Voltage, Approximately 0–5V
Digital Output HIGH/LOW, TTL Logic
Digital Output Levels Approximately 0V or 5V
Detection Threshold Adjustment Onboard Potentiometer
Interface Analog and Digital
Sensor Heating Internal Heating Element
Preheating Required for Stable Measurements
Module Connection 4-Pin Interface

Pin Configuration

Pin Description
VCC 5V DC Power Supply
GND Ground
AO Analog Gas Sensor Output
DO Digital Threshold Output

Arduino UNO Connection Example

MQ-6 Pin Arduino UNO
VCC 5V
GND GND
AO A0
DO D2 (Optional)

The Arduino can monitor relative changes in LPG concentration using the analog output or detect when the adjustable digital threshold is reached.

ESP32 Connection Example

MQ-6 Pin ESP32
VCC 5V
GND GND
AO GPIO34 Through Voltage Divider
DO Digital GPIO Through Level Shifter

Important: The MQ-6 module operates at 5V, while ESP32 GPIO pins operate at 3.3V. Use an appropriate voltage divider or level shifter before connecting the sensor outputs.

Raspberry Pi Compatibility

The MQ-6 can be used with Raspberry Pi boards for LPG sensing experiments.

  • Analog Reading: Requires an external ADC module such as ADS1115 or MCP3008.
  • Digital Reading: Requires suitable 5V-to-3.3V level shifting.
  • Power Supply: Requires a suitable 5V power source.

Applications

  • LPG detection experiments
  • Propane and butane sensing projects
  • Gas monitoring prototypes
  • Arduino and ESP32 gas detection systems
  • IoT combustible gas monitoring
  • Smart home automation experiments
  • Educational electronics projects
  • Environmental sensing demonstrations
  • Industrial gas monitoring research
  • Robotics and embedded sensor systems
  • Automated ventilation prototypes

Important Notes

  • The MQ-6 is primarily designed for LPG, propane, butane, and isobutane detection.
  • The sensor may respond to other combustible gases and cannot reliably identify individual gases in a mixed environment.
  • The analog output does not directly provide gas concentration in ppm. Accurate measurements require calibration.
  • The onboard potentiometer adjusts the digital detection threshold, not the sensor's underlying sensitivity.
  • The sensor requires preheating before stable readings can be obtained. Initial conditioning may require extended operation according to manufacturer recommendations.
  • Temperature, humidity, and airflow can affect sensor readings.
  • The internal heating element becomes warm during operation.
  • Do not connect the module's 5V output signals directly to 3.3V-only GPIO pins.
  • The MQ-6 is intended for educational, experimental, and non-safety-critical monitoring applications.
  • This module is not a certified LPG leakage alarm and must not replace approved combustible gas safety detectors.

Package Includes

  • 1 × MQ-6 LPG Gas Sensor Module