The MQ131 Ozone Gas Sensor Module is a compact semiconductor gas sensor designed to detect ozone (O₃) concentrations in the surrounding air. It uses a metal oxide sensing element, typically based on tin dioxide (SnO₂), whose electrical conductivity changes when exposed to ozone.

The MQ131 sensor family includes versions designed for low ozone concentrations (10–1,000 ppb) and high ozone concentrations (10–1,000 ppm). The appropriate measurement range depends on the installed sensor variant.

This module features analog and digital outputs, an adjustable threshold potentiometer, and a compact PCB design, making it suitable for Arduino, ESP32, Raspberry Pi, and other microcontroller-based monitoring projects.

It is suitable for air quality monitoring experiments, environmental research, ozone generator testing, and educational electronics applications.

Key Features

  • Ozone Detection: Designed to detect ozone (O₃) in the surrounding air.
  • Sensitive Semiconductor Element: Detects changes in ozone concentration through changes in sensor resistance.
  • Analog Output (AO): Provides a variable voltage related to sensor response.
  • Digital Output (DO): Provides a HIGH/LOW signal when the adjustable detection threshold is reached.
  • Adjustable Threshold: Onboard potentiometer allows adjustment of the digital switching point.
  • LED Indicators: Onboard indicators for power and detection status, depending on PCB configuration.
  • Compact Design: Suitable for integration into electronic monitoring projects.
  • Microcontroller Compatibility: Can interface with Arduino, ESP32, Raspberry Pi, and other development boards using appropriate circuitry.

Technical Specifications

Specification Details
Model MQ131
Sensor Type Ozone Gas Sensor
Target Gas Ozone (O₃)
Sensor Technology Metal Oxide Semiconductor (MOS)
Sensing Material Typically SnO₂
Low-Concentration Version 10–1,000 ppb O₃
High-Concentration Version 10–1,000 ppm O₃
Module Supply Voltage Depends on Module Version
Output Type Analog and Digital
Analog Output Variable Voltage
Digital Output HIGH/LOW Logic
Detection Threshold Adjustable Potentiometer
Preheating Required Before Stable Measurements
Sensor Interface Analog / Digital
PCB Mounting Compact Board with Mounting Holes

Pin Configuration

Pin Description
VCC Module Power Supply
GND Ground
AO Analog Sensor Output
DO Digital Threshold Output

Arduino UNO Connection Example

MQ131 Pin Arduino UNO
VCC Module-Rated Supply
GND GND
AO A0
DO D2 (Optional)

Arduino can monitor relative changes in ozone concentration using the analog output or detect when the adjustable digital threshold is reached.

Accurate ozone concentration measurements require calibration using the correct sensor characteristics.

ESP32 Connection Example

MQ131 Pin ESP32
VCC Module-Rated Supply
GND GND
AO GPIO34 Through Suitable Voltage Divider
DO Digital GPIO Through Level Shifter

Important: ESP32 GPIO pins operate at 3.3V. Use appropriate signal conditioning if the module outputs exceed 3.3V.

Raspberry Pi Compatibility

The MQ131 can be connected to Raspberry Pi boards using additional interface components.

  • Analog Reading: Requires an external ADC such as ADS1115 or MCP3008.
  • Digital Reading: Requires suitable voltage-level protection if the digital output exceeds 3.3V.
  • Power Supply: Must match the installed module's voltage requirements.

Applications

  • Ozone gas monitoring experiments
  • Indoor and outdoor air quality research
  • Environmental monitoring prototypes
  • Ozone generator testing
  • Laboratory ozone sensing
  • Arduino and ESP32 gas sensor projects
  • Raspberry Pi data logging systems
  • IoT environmental monitoring
  • Educational electronics experiments
  • Industrial ozone monitoring prototypes
  • Embedded gas detection systems

Important Notes

  • The MQ131 sensor family includes different low- and high-concentration versions.
  • The 10–1,000 ppb and 10–1,000 ppm ranges refer to different sensor variants, not one continuous measurement range.
  • The exact detection range and operating voltage must be confirmed against the installed sensor version.
  • The sensor may respond to other oxidizing gases, including nitrogen dioxide (NO₂) and chlorine (Cl₂).
  • The analog output does not directly represent ozone concentration in ppb or ppm. Calibration is required.
  • The onboard potentiometer adjusts the digital switching threshold, not the sensor's underlying sensitivity.
  • Initial preheating and sensor conditioning are required.
  • Temperature, humidity, and other environmental conditions may affect measurements.
  • Different MQ131 sensor variants may require different heater voltages.
  • Do not connect 5V output signals directly to 3.3V-only microcontroller GPIO pins.
  • Ozone is hazardous. Testing should be performed using appropriate safety precautions and ventilation.
  • This module is intended for educational and experimental monitoring and is not a certified ozone exposure safety detector.

Package Includes

  • 1 × MQ131 Ozone Gas Sensor Module