The MQ139 Freon Refrigerant Gas Sensor Module is a semiconductor gas sensor designed to detect certain refrigerant gases in the surrounding air. It is suitable for refrigeration monitoring experiments, HVAC research, gas detection prototypes, and educational electronics projects.
The sensor operates by detecting changes in the electrical resistance of its gas-sensitive element when exposed to detectable gases.
Featuring analog and digital outputs, an adjustable detection threshold, an onboard indicator LED, and a compact PCB design, the MQ139 can be integrated with Arduino, ESP32, Raspberry Pi, and other microcontroller-based monitoring systems using appropriate interface circuitry.
Key Features
-
Refrigerant Gas Detection: Designed for sensing certain Freon-type refrigerant gases.
-
Semiconductor Sensing Technology: Detects changes in gas concentration through variations in sensor resistance.
-
Analog Output (AO): Provides a variable voltage related to the sensor response.
-
Digital Output (DO): Provides a HIGH/LOW signal based on an adjustable threshold.
-
Adjustable Detection Threshold: Onboard potentiometer allows adjustment of the digital switching point.
-
5V DC Operation: Suitable for common microcontroller development platforms.
-
Onboard Indicator LED: Indicates the digital output status.
-
Fast Response and Recovery: Responds to changes in detectable gas concentrations.
-
Compact PCB Design: Suitable for electronics prototypes and embedded applications.
-
Mounting Holes: Allows installation in project enclosures.
-
Removable Sensor Element: The sensor probe can be removed from its socket for testing or replacement, where supported by the module design.
Technical Specifications
| Specification |
Details |
| Model |
MQ139 |
| Sensor Type |
Refrigerant Gas Sensor |
| Target Gas |
Certain Freon-Type Refrigerants |
| Sensor Technology |
Semiconductor Gas Sensor |
| Operating Voltage |
5V DC |
| Reported Detection Range |
10–1000 ppm (gas-dependent) |
| Analog Output |
Variable Voltage |
| Digital Output |
HIGH/LOW Logic |
| Digital Output Active State |
LOW (reported module behavior) |
| Detection Threshold |
Adjustable Potentiometer |
| Output Indicator |
Onboard LED |
| Module Dimensions |
Approximately 35 × 21 × 28 mm |
| Interface |
Analog and Digital |
| Mounting |
PCB Mounting Holes |
Pin Configuration
| Pin |
Description |
| VCC |
5V DC Power Supply |
| GND |
Ground |
| AO |
Analog Gas Sensor Output |
| DO |
Digital Threshold Output |
Arduino UNO Connection Example
| MQ139 Pin |
Arduino UNO |
| VCC |
5V |
| GND |
GND |
| AO |
A0 |
| DO |
D2 (Optional) |
The Arduino can read the analog output to monitor relative changes in detectable refrigerant gas levels or use the digital output to identify when the adjustable threshold is reached.
Note: Accurate gas concentration measurements require calibration with the specific target refrigerant.
ESP32 Connection Example
| MQ139 Pin |
ESP32 |
| VCC |
5V |
| GND |
GND |
| AO |
GPIO34 Through Voltage Divider |
| DO |
Digital GPIO Through Level Shifter |
Important: ESP32 GPIO pins operate at 3.3V. The MQ139 module may produce output signals up to 5V, so appropriate voltage-level protection is required.
Raspberry Pi Compatibility
The MQ139 can be interfaced with Raspberry Pi boards using additional components.
-
Analog Reading: Requires an external ADC such as ADS1115 or MCP3008.
-
Digital Reading: Requires appropriate voltage-level shifting when the output exceeds 3.3V.
-
Power Supply: Requires a suitable 5V DC supply.
Applications
- Refrigerant gas detection experiments
- HVAC monitoring research
- Refrigeration system monitoring prototypes
- Air conditioning maintenance research
- Arduino gas sensing projects
- ESP32 IoT monitoring applications
- Raspberry Pi sensor projects
- Educational electronics experiments
- Laboratory refrigerant sensing research
- Embedded gas monitoring systems
- Environmental sensing prototypes
- Refrigerant leak detection demonstrations
Important Notes
- The MQ139 is intended for detecting certain refrigerant gases; sensitivity varies depending on the refrigerant type.
- Compatibility with a specific refrigerant, such as R134a, R22, R32, or R410A, must be confirmed using the manufacturer's sensor documentation.
- The reported 10–1000 ppm detection range is not guaranteed for every refrigerant.
- The analog output requires calibration before it can be used to estimate gas concentration.
- The onboard potentiometer adjusts the digital detection threshold.
- Initial preheating and sensor conditioning are required for stable measurements.
- Temperature, humidity, and other environmental conditions may affect sensor readings.
- The sensor's internal heating element becomes warm during operation.
- Do not connect 5V output signals directly to 3.3V-only GPIO pins.
- This module is intended for electronics development, experimentation, and research.
- It is not a certified refrigerant leak detector and must not replace professional HVAC leak detection or safety equipment.
Package Includes