Robot Pi Shop

EMG Muscle Signal Sensor

$25.99

Shipping calculated at checkout.

Quantity

EMG Muscle Signal Sensor Kit with Electrodes – Adjustable Gain

The EMG Muscle Signal Sensor Kit allows you to detect and measure the electrical activity produced by skeletal muscles during contraction.

Electromyography (EMG) measures the electrical potential generated by muscle activity. This sensor processes the detected EMG signal and provides a filtered and rectified analog voltage output, making it easier to read with Arduino and other compatible controllers.

As muscle activity increases, the output voltage changes accordingly, allowing muscle contractions to be used as an input for robotics, interactive electronics, prosthetic research projects and human-machine interfaces.

The kit includes the muscle sensor board, 60cm electrode cable and three disposable surface electrodes, providing the essential components needed to begin experimenting with EMG signals.

Technical Specifications

  • Sensor Type: Surface Electromyography (EMG) Sensor
  • Measurement: Electrical Muscle Activity
  • Output: Filtered & Rectified Analog Signal
  • Output Range: Approximately 0V to Vs, depending on muscle activity and circuit configuration
  • Gain: Adjustable
  • Minimum Supply Requirement: ±3.5V
  • Board Dimensions: Approx. 25 × 25mm
  • Electrode Connection: 3 Electrodes
  • Electrode Cable Length: Approx. 60cm
  • Designed For: Microcontrollers & Data Acquisition
  • Form Factor: Compact

Measures Electrical Muscle Activity

When skeletal muscles contract, small electrical potentials are generated by the activity of muscle fibers.

The EMG sensor detects these signals using electrodes attached to the skin.

The onboard circuitry then conditions the signal to provide a more convenient analog output for electronic projects.

In general:

Relaxed Muscle → Lower Output

Increased Muscle Activity → Higher Output

The exact signal level varies according to the muscle, electrode placement, gain setting and individual user.

Filtered & Rectified Analog Output

Raw EMG signals are small, bipolar and relatively difficult to use directly with a microcontroller.

This sensor processes the muscle signal and provides a filtered and rectified output, simplifying measurement with an analog-to-digital converter.

The output varies approximately between:

0V and Vs

where Vs represents the relevant circuit supply/output reference voltage.

This allows software to monitor the signal and establish thresholds for detecting muscle activation.

Adjustable Gain

The sensor provides adjustable gain, allowing the sensitivity of the EMG measurement to be adapted to the application.

Gain adjustment can be useful because EMG signal strength varies according to:

  • Muscle Group
  • Electrode Position
  • Electrode Contact
  • Individual User
  • Strength of Muscle Contraction
  • Electrical Noise
  • Movement

Calibration should therefore be performed for each application and user.

3-Electrode Measurement

The kit includes three disposable surface electrodes for detecting muscle activity.

For best results:

  • Clean and dry the skin before applying electrodes.
  • Position the sensing electrodes over the target muscle.
  • Use the reference electrode according to the sensor's recommended placement.
  • Ensure good electrode-to-skin contact.
  • Keep electrode cables secure during measurement.

Correct electrode placement is essential for obtaining a stable and useful EMG signal.

60cm Electrode Cable

The included 60cm cable lead connects the surface electrodes to the EMG sensor board.

The cable provides sufficient flexibility for experimenting with different muscle groups while keeping the sensor electronics conveniently positioned.

Arduino & Microcontroller Projects

The processed analog output can be read by a compatible microcontroller ADC.

A typical system works as follows:

Muscle Activity → Electrodes → EMG Sensor → Analog Output → Microcontroller

Software can then process the signal and use muscle activity to control another device.

Possible outputs include:

  • Servo Motors
  • Robot Grippers
  • LEDs
  • Displays
  • Buzzers
  • Motors through a Suitable Driver
  • Robotic Arms
  • Interactive Devices

Muscle-Controlled Robotics

The sensor is particularly useful for experimenting with muscle-controlled robotic systems.

For example:

Relaxed Muscle → Gripper Open

Muscle Contraction → Gripper Close

The microcontroller can monitor the EMG output and activate a servo or motor when the signal exceeds a programmed threshold.

More advanced projects can use filtering, calibration and multiple sensors to create more sophisticated human-machine interfaces.

Applications

Ideal for:

  • Muscle-Controlled Robotics
  • Robotic Arms
  • Robot Grippers
  • Human-Machine Interfaces
  • Biomedical Engineering Education
  • Prosthetic Research Projects
  • Arduino Projects
  • Interactive Electronics
  • Wearable Electronics Experiments
  • Biomechanics Projects
  • University Projects
  • STEM Education
  • Muscle Activity Experiments
  • Data Acquisition
  • Research Prototypes

Improving Signal Quality

EMG signals are small and can be affected by electrical interference.

For better measurements:

  • Ensure good electrode contact.
  • Keep the skin clean and dry.
  • Secure electrode cables to reduce movement artifacts.
  • Keep sensor wiring away from motors and switching power supplies.
  • Avoid running signal cables close to mains wiring.
  • Adjust the gain carefully.
  • Establish software thresholds after observing the user's relaxed and contracted muscle signals.

Important Power Supply Note

The specified minimum supply requirement is:

±3.5V

The ± symbol is important and should not be interpreted simply as a single +3.5V supply.

Use the power arrangement specified for this particular EMG sensor board.

Do not substitute the power specifications of newer EMG boards such as MyoWare 2.0, as they use a different electrical design.

Safety & Intended Use

This sensor is intended for:

Education, experimentation, prototyping and research projects.

It should not be used for medical diagnosis, patient monitoring or other safety-critical medical applications unless the complete system has the appropriate medical certification.

When attaching electronic equipment to the human body:

  • Use appropriate surface electrodes.
  • Do not place electrodes on broken or irritated skin.
  • Follow correct electrode-placement procedures.
  • Avoid unsafe connections to mains-powered equipment.
  • Use an appropriately isolated or battery-powered measurement setup.
  • Never intentionally pass electrical current through the body using this sensor.

The electrodes are intended to measure naturally occurring electrical muscle activity, not electrically stimulate the muscle.

Important Notes

  • Measures electrical muscle activity, not physical muscle force directly.
  • Provides a processed analog EMG output.
  • Gain is adjustable.
  • Output varies with electrode placement and muscle activity.
  • Calibration is recommended for each user and muscle group.
  • Board dimensions are approximately 25 × 25mm.
  • Requires the correct dual-rail power arrangement specified for the sensor.
  • Disposable electrodes should be replaced when adhesion or signal quality deteriorates.
  • This product is intended for educational and experimental applications.

Kit Includes

  • 1 × EMG Muscle Sensor Board
  • 1 × 60cm Electrode Cable Lead
  • 3 × Disposable Surface Electrodes